Horizontal pillar technique: A single pedicle septum-based approach in reduction mammaplasty with a twist


AKYÜREK M., HAFIZ G.

Journal of Plastic, Reconstructive and Aesthetic Surgery, cilt.87, ss.33-40, 2023 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 87
  • Basım Tarihi: 2023
  • Doi Numarası: 10.1016/j.bjps.2023.09.010
  • Dergi Adı: Journal of Plastic, Reconstructive and Aesthetic Surgery
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, MEDLINE
  • Sayfa Sayıları: ss.33-40
  • Anahtar Kelimeler: Breast reduction, Breast-Q, Macromastia, Reduction mammaplasty
  • Çanakkale Onsekiz Mart Üniversitesi Adresli: Evet

Özet

Breast reduction surgery has proven to be a successful treatment for various conditions such as postural disorders, anxiety, dermatological problems, and body image disorders, and is tailored to accommodate each patient's needs and anatomical variations. The author presents a modified approach for reduction mammaplasty using a septum-based superomedial pedicled nipple-areola complex (NAC) flap combined with horizontal dermoglandular pillars. This adjustment enhances desired breast projection, potentially eliminating the need for alternative pedicles in most cases. The limitations and disadvantages of this new technique are discussed. Between July 2015 and July 2021, 85 patients underwent surgery using the horizontal pillar reduction mammaplasty. Clinical data obtained during follow-up visits were recorded. Patients were asked to answer the local version of the Breast-Q, version 2.0, reduction module postoperative scale questionnaire to evaluate breast shape contentment and patient satisfaction at the 1-year follow-up. Necrosis of the NAC was not observed in any patient. The most common complaints in the early postoperative period were pain along the inframammary fold and swelling that extended into the axillary region. The mean values and standard deviations of the postoperative Breast-Q scores were calculated. The postoperative satisfaction with breasts scale mean value was 84.11 ± 12.86, and the postoperative satisfaction with outcomes scale mean value was 81.08 ± 9.97. The horizontal pillar reduction mammaplasty technique is safe, reliable, and easy to perform in breast reduction. Although the initial findings are encouraging, future anatomical and clinical studies are necessary to fully explore this modified technique's functional limitations and long-term outcomes.